Wells RCP-Series Specifikace

Procházejte online nebo si stáhněte Specifikace pro Sporáky Wells RCP-Series. Wells RCP-Series Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 18
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
PRINTED IN UNITED STATES OF AMERICA
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
www.wellsbloomfield.com
telephone: 775-689-5703
fax: 775-689-5976
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
OPERATION MANUAL
RCP-Series
DROP-IN
REFRIGERATED
COLD PANS
MODELS
RCP-100 RCP-7100
RCP-200 RCP-7200
RCP-300 RCP-7300
RCP-400 RCP-7400
RCP-500 RCP-7500
RCP-600 RCP-7600
Includes
INSTALLATION
USE & CARE
405
p/n 305101 Rev. D ECN-13538 M405 080915 cps
Model RCP-200
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - COLD PANS

PRINTED IN UNITED STATES OF AMERICAWELLS BLOOMFIELD, LLC2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439www.wellsbloomfield.comtelephone: 775-689-5703fax:

Strany 2 - LIMITED WARRANTY STATEMENT

OPERATION NOTES 1. Never place food directly in cold pans. Always use insets or food pans. 2. Use only pre-chilled products. Stir product occasi

Strany 3 - INTRODUCTION

CLEANING INSTRUCTIONS 9 CAUTION: ELECTRIC SHOCK HAZARD DO NOT splash or pour water onto control panel or wiring. IMPORTANT: DO NOT use steel woo

Strany 4

10 CONDENSER COIL CLEANING INSTRUCTIONS The condenser coil must be kept clean to allow adequate air flow for proper heat dissipation. Recommend this

Strany 5

11 CAUTION: PERSONAL INJURY HAZARD Disconnect appliance from electrical power before cleaning. Wells refrigerated cold pans are constructed of high

Strany 6 - AGENCY LISTING INFORMATION

12 MAINTENANCE INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT RCP-100 thru RCP-600 1. The temperature has been preset at the factory to meet most

Strany 7 - PREPARATION

13 MAINTENANCE INSTRUCTIONS (continued) IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the diff

Strany 8 - INSTALLATION (continued)

14 TROUBLESHOOTING SUGGESTIONS 405 p/n 305101 OpM RCP Refrigerated Cold Pans

Strany 9

DESCRIPTION PART NO. DRAIN SCREEN 21709 SOUP LADEL, 6 oz. 21764 ADAPTER BAR FOR 12" X 20" PANS 22016 P

Strany 10 - CAUTION:

Genuine PartsProtect - YOU - All - WaysSERVICE TRAINING - QUALITY SERVICESERVICE TRAINING - QUALITY SERVICECUSTOMER SATISFACTIONCUSTOMER SATISFACTIONW

Strany 11 - CLEANING INSTRUCTIONS

405 p/n 305101 OpM RCP Refrigerated Cold Pans All commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects i

Strany 12 - MAINTENANCE INSTRUCTIONS

WARRANTY xi SPECIFICATIONS FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY L

Strany 13

FEATURES & OPERATING CONTROLS 2 NOTE: This is a general arrangement drawing only. Actual component positions may vary between units. 405 p/n 30

Strany 14 - TEMPERATURE ADJUSTMENT

3 This appliance is intended for use in commercial establishments only, and is intended to hold pre-chilled prepared food for human consumption. No

Strany 15

4 AGENCY LISTING INFORMATION 405 p/n 305101 OpM RCP Refrigerated Cold Pans This appliance is performance tested to NSF Standard 4 for holding hot foo

Strany 16 - TROUBLESHOOTING SUGGESTIONS

INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for pr

Strany 17 - CUSTOMER SERVICE DATA

6 WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated elec-trical components must be performed by a factory au-thorized

Strany 18 - Genuine Parts

7 IMPORTANT: Plumbing connections must be made in compliance with all Federal, State and Local Codes and Ordinances. IMPORTANT: All drain plumbing in