Operation and Care Manual #8452/53/55
PG.9
CONTROLS FUNCTIONS OPERATION
FRYER
CONTROL PANEL
ITEM POWER SWITCH (FRYER OFF FILTER)
Pressing the switch on the fryer control
panel to the "FRYER" position will energize
the ventilator.
ITEM VENTILATOR POWER ON INDICATOR
(
GREEN)
When the fryer is energized, the ventilator
power ON indicator light will illuminate
and the blower will begin to operate for a
period of 10 seconds.
If sufficient air flow is established within
this 10 second period, the power on light
will remain illuminated and the fryer will
be operational.
If there is not sufficient air flow for proper
operation within this 10 second period, the
blower and ventilator power light will turn
OFF, the service required light will
illuminate, and the fryer will not operate.
Insufficient air flow requires the operator
to switch the fryer control to the
OFF
position for a short period of time before
attempting to reestablish operation.
Under normal operation, the green ventilator
power
ON indicator will be the only light
illuminated on the ventilator panel.
ITEM CHECK FILTERS INDICATOR (AMBER)
The check filters indicator will illuminate
when the Grease Vapor HEPA filter is
missing or not properly installed or the
Stainless Steel Baffle filter is not properly
installed. When the check filters light is
illuminated, the fryer is inoperable.
If the check filters light illuminates, check
both the Stainless Steel Baffle filter and
Grease Vapor HEPA filter for proper
installation. Always replace the HEPA
filter and charcoal filter at the same time.
When the check filters light is off, the fryer
will operate normally.
ITEM REPLACE FILTERS INDICATOR (AMBER)
The "Replace Filter" light is directly tied to
an air flow diagnostic device which
measures the air pressure through the filter
system. This light will illuminate when the
Grease Vapor filter and the Odor Control
filter accumulates a sufficient amount of
grease build-up to impede air flow. This
light is a clear indication to replace both
filters. While the fryer will still operate
normally, the air filter must be changed in
a timely manner or the service required
light will illuminate and the fryer will not
operate until the air filters have been
replaced.
ITEM SERVICE REQUIRED INDICATOR (RED)
Failure to replace Odor Control and the
Grease Vapor HEPA filters within
approximately one week from the date the
"Replace Filter" light illuminates will result
in the illumination of the "Service
Required" indicator. Once the "Service
Required" light is illuminated, the fryer
will become inoperable until both filters
are replaced. Once the filters are replaced,
reset the fryer by pressing the power
switch to the
OFF position, immediately
followed by pressing the switch of the
Fryer to the
ON position.
SERVICE POWER FAILURE
If the shutdown is caused by a service power
failure, the fryer can be restarted by cycling the
power switch to
OFF and then ON.